Sampling + Analysis Guide

Butadiene
CAS #:
106-99-0
Fee Per Sample:
$63.00
Method + Notes:
mod. NIOSH 1024; GC/FID
A minimum air volume of 30L is required to meet 1/10 the OSHA PEL. Separate tubes after sample collection. Samples must be chilled to below 4 degrees C during storage and shipment. Interferences: pentane, methyl acetylene, and vinylidene chloride when present at high concentrations and high humidity
Analytical Technique:
GC/FID
Collection Medium:
Charcoal
Order Number:
226-37
Media Shelf Life (Years):
5 yrs.
Comp Code:
Air Vol (L):
5-25 L
Sampling Rate (LPM):
0.01-0.5 LPM
LOQ:
5 ug