Sampling + Analysis Guide

Benzene [2]
CAS #:
71-43-2
Fee Per Sample:
$52.00
Method + Notes:
mod. NIOSH 1501; GC/FID BADGE
For best sampling results, include the charcoal scavenger packet with your returned sampling media. Manufacturer recommends returning samples to the laboratory within 14 days of the sampling event. For the N566 model, a minimum sampling time of 75min is required to meet the OSHA PEL & 150min is required to meet the TLV. For the N521 model (both covers removed) a minimum sampling time of 20min is required to meet the TLV. N521 model with both covers removed is recommended for STEL sampling (N566 will not meet TLV-STEL or REL-STEL).
Analytical Technique:
GC/FID
Collection Medium:
PM
Order Number:
N566/ N521
Media Shelf Life (Years):
mfg. exp. date/ mfg. exp. date
Comp Code:
U
Air Vol (L):
15 min.- 12 hrs.
Sampling Rate (LPM):
LOQ:
2 ug